    <notes>
        Profile Molsmart GW8 AC Learning
        Permite o controle de ar condicionado pelo GW8 (controles cadastrados no GW8) ao sistema Savant
        -Instrucoes:
        Primeiramente deve-se cadastrar o controle do ar condicionado no GW8, pela interface web
        do GW8, conforme manual do fabricante
        Insira o profile ao sistema - sete o IP conforme o endereco ja reservado
        Faca as conexoes necessarias (Ethernet apenas)
        Gere os servicos

        No profile isnpecting colocar os valores na State Variables:
        user_gateway=usuário do GW8 (padrão: admin)
        password_gateway=senha do GW8 (padrão: 12345678)


        Ar condicionado:
        Vá em Tools/Settings/HVAC e insira os dados do ar condicionado informando o nome desejado,
        ambiente e atributos conforme abaixo
        Address 1: Número da zona (1-8) - deve corresponder ao controle_ar_N e canal_ir_N nas State Variables

        No profile inspecting colocar os valores nas State Variables para cada AR:
        controle_ar_N = cID do controle no GW8 (retirado na interface web do GW8)
        canal_ir_N    = canal IR fisico do GW8 (porta 1-8)


    </notes>
    <control_interfaces preferred="ip">
        <ip name_on_component="LAN" response_time_length_ms="500" port="80" protocol="http">
            <send_prefix type="character"></send_prefix>
            <send_postfix type="character"></send_postfix>
        </ip>
    </control_interfaces>
    <media_interfaces>
        <data name_on_component="LAN">
            <combined_media>
                <data_media type="ethernet"></data_media>
                <control port="80"></control>
            </combined_media>
        </data>
        <internal name_on_component="HVAC_controller">
            <environmental_media></environmental_media>
            <resource resource_type="ENV_HVACCONTROLLER_SOURCE" />
        </internal>
    </media_interfaces>
    <state_variable_list>
        <!-- variaveis do gateway -->
        <state_variable name="user_gateway" state_center_type="string" user_editable="yes">admin</state_variable>
        <state_variable name="password_gateway" state_center_type="string" user_editable="yes">12345678</state_variable>
        <state_variable name="tipo_do_dispositivo" state_center_type="string" user_editable="no">52</state_variable>
        <!-- controles de AR condicionado: cID do controle no GW8 -->
        <state_variable name="controle_ar_1" state_center_type="string" user_editable="yes">controle_ar_1</state_variable>
        <state_variable name="controle_ar_2" state_center_type="string" user_editable="yes">controle_ar_2</state_variable>
        <state_variable name="controle_ar_3" state_center_type="string" user_editable="yes">controle_ar_3</state_variable>
        <state_variable name="controle_ar_4" state_center_type="string" user_editable="yes">controle_ar_4</state_variable>
        <state_variable name="controle_ar_5" state_center_type="string" user_editable="yes">controle_ar_5</state_variable>
        <state_variable name="controle_ar_6" state_center_type="string" user_editable="yes">controle_ar_6</state_variable>
        <state_variable name="controle_ar_7" state_center_type="string" user_editable="yes">controle_ar_7</state_variable>
        <state_variable name="controle_ar_8" state_center_type="string" user_editable="yes">controle_ar_8</state_variable>
        <!-- canal IR fisico do GW8 para cada AR (porta 1-8) -->
        <state_variable name="canal_ir_1" state_center_type="string" user_editable="yes">1</state_variable>
        <state_variable name="canal_ir_2" state_center_type="string" user_editable="yes">1</state_variable>
        <state_variable name="canal_ir_3" state_center_type="string" user_editable="yes">1</state_variable>
        <state_variable name="canal_ir_4" state_center_type="string" user_editable="yes">1</state_variable>
        <state_variable name="canal_ir_5" state_center_type="string" user_editable="yes">1</state_variable>
        <state_variable name="canal_ir_6" state_center_type="string" user_editable="yes">1</state_variable>
        <state_variable name="canal_ir_7" state_center_type="string" user_editable="yes">1</state_variable>
        <state_variable name="canal_ir_8" state_center_type="string" user_editable="yes">1</state_variable>
        <!-- variaveis do ar  -->
        <state_variable name="Current_Cool_Point_Setting_1" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_1">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_1" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_1">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_1" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_1">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_1"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_1">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_1"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_1">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_1" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_1">true</state_variable>

        <state_variable name="Current_HVAC_Mode_1" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_1"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_1" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_1"
            max_value="1">0</state_variable>


        <state_variable name="Current_Cool_Point_Setting_2" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_2">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_2" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_2">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_2" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_2">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_2"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_2">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_2"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_2">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_2" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_2">true</state_variable>

        <state_variable name="Current_HVAC_Mode_2" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_2"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_2" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_2"
            max_value="1">0</state_variable>

        <state_variable name="Current_Cool_Point_Setting_3" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_3">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_3" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_3">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_3" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_3">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_3"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_3">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_3"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_3">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_3" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_3">true</state_variable>

        <state_variable name="Current_HVAC_Mode_3" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_3"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_3" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_3"
            max_value="1">0</state_variable>

        <state_variable name="Current_Cool_Point_Setting_4" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_4">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_4" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_4">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_4" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_4">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_4"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_4">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_4"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_4">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_4" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_4">true</state_variable>

        <state_variable name="Current_HVAC_Mode_4" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_4"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_4" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_4"
            max_value="1">0</state_variable>

        <state_variable name="Current_Cool_Point_Setting_5" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_5">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_5" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_5">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_5" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_5">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_5"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_5">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_5"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_5">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_5" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_5">true</state_variable>

        <state_variable name="Current_HVAC_Mode_5" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_5"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_5" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_5"
            max_value="1">0</state_variable>

        <state_variable name="Current_Cool_Point_Setting_6" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_6">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_6" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_6">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_6" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_6">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_6"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_6">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_6"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_6">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_6" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_6">true</state_variable>

        <state_variable name="Current_HVAC_Mode_6" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_6"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_6" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_6"
            max_value="1">0</state_variable>

        <state_variable name="Current_Cool_Point_Setting_7" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_7">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_7" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_7">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_7" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_7">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_7"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_7">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_7"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_7">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_7" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_7">true</state_variable>

        <state_variable name="Current_HVAC_Mode_7" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_7"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_7" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_7"
            max_value="1">0</state_variable>

        <state_variable name="Current_Cool_Point_Setting_8" min_value="16" max_value="32"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentCoolPoint_8">20</state_variable>
        <state_variable name="Current_Heat_Point_Setting_8" min_value="18" max_value="29"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="no"
            state_center_type="string" state_center_binding="ThermostatCurrentHeatPoint_8">20</state_variable>
        <state_variable name="Thermostat_Current_Temperature_8" min_value="17" max_value="30"
            owning_logical_component="HVAC_controller" receive_updates_from_state_center="yes"
            state_center_type="string" state_center_binding="ThermostatCurrentTemperature_8">--</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Heat_8"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeHeat_8">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Cool_8"
            owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeCool_8">false</state_variable>
        <state_variable name="Is_Current_HVAC_Mode_Off_8" owning_logical_component="HVAC_controller"
            receive_updates_from_state_center="yes" state_center_type="boolean"
            state_center_binding="IsCurrentHVACModeOff_8">true</state_variable>

        <state_variable name="Current_HVAC_Mode_8" state_center_type="integer" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="Current_HVAC_Mode_8"
            max_value="3" /><!-- 0 - OFF, 1 - COOL, 2 - HEAT, 3 - AUTO -->
        <state_variable name="HasReceivedCommand_8" state_center_type="string" min_value="0"
            owning_logical_component="HVAC_controller" state_center_binding="HasReceivedCommand_8"
            max_value="1">0</state_variable>


    </state_variable_list>
    <logical_component logical_component_name="HVAC_controller">
        <implementation>
            <internal name_on_component="HVAC Controller" />
        </implementation>
        <universal_component_actions>
            <action name="PowerOn">
                <command_interface interface="ip">
                    <command response_required="no">
                        <command_string type="character" http_request_type="GET">info?type=1</command_string>
                        <delay ms_delay="500" />
                    </command>
                </command_interface>
                <execute_on_schedule period_ms="0"></execute_on_schedule>
            </action>
        </universal_component_actions>
        <!--************************************************************************************************************************-->
        <!--**********************************************
        HVAC / AR CONDICIONADO
        ThermostatAddress = numero da zona (1-8)
        cId  vem de controle_ar_N (state variable)
        c=   vem de canal_ir_N    (state variable)
        **********************************************-->
        <!--************************************************************************************************************************-->
        <resource_component_actions resource_type="ENV_HVACCONTROLLER_SOURCE">
            <action name="SetCoolPointTemperature">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <action_argument name="CoolPointTemperature" note="" />
                <update_state_variable name="Current_Cool_Point_Setting_*" update_type="set"
                    wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@"
                    update_source="action_argument">CoolPointTemperature</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Current_HVAC_Mode_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="state_variable">Current_Cool_Point_Setting_*</update_state_variable>
                <command_interface interface="ip">
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;t=</parameter>
                            <parameter state_variable="Current_Cool_Point_Setting_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                        </parameter_list>
                        <delay ms_delay="1000"></delay>
                    </command>
                </command_interface>
            </action>
            <action name="SetHeatPointTemperature">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <action_argument name="HeatPointTemperature" note="" />
                <update_state_variable name="Current_Heat_Point_Setting_*" update_type="set"
                    wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@"
                    update_source="action_argument">HeatPointTemperature</update_state_variable>
                <update_state_variable name="Current_HVAC_Mode_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">2</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <command_interface interface="ip">
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;t=</parameter>
                            <parameter state_variable="Current_Heat_Point_Setting_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" />
                        </parameter_list>
                        <delay ms_delay="1000"></delay>
                    </command>
                </command_interface>
            </action>
            <action name="SetHVACModeHeat">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <action_argument name="HeatPointTemperature" note="" />
                <update_state_variable name="Is_Current_HVAC_Mode_Heat_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">true</update_state_variable>
                <update_state_variable name="Is_Current_HVAC_Mode_Cool_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">false</update_state_variable>
                <update_state_variable name="Is_Current_HVAC_Mode_Off_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">false</update_state_variable>
                <update_state_variable name="Current_HVAC_Mode_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">2</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="action_argument">HeatPointTemperature</update_state_variable>
                <command_interface interface="ip">
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;t=</parameter>
                            <parameter state_variable="Current_Heat_Point_Setting_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                        </parameter_list>
                        <delay ms_delay="1000"></delay>
                    </command>
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;t=</parameter>
                            <parameter state_variable="Current_Heat_Point_Setting_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                        </parameter_list>
                        <delay ms_delay="1500"></delay>
                    </command>
                </command_interface>
            </action>
            <action name="SetHVACModeCool">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <action_argument name="CoolPointTemperature" note="" />
                <update_state_variable name="Is_Current_HVAC_Mode_Heat_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">false</update_state_variable>
                <update_state_variable name="Is_Current_HVAC_Mode_Cool_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">true</update_state_variable>
                <update_state_variable name="Is_Current_HVAC_Mode_Off_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">false</update_state_variable>
                <update_state_variable name="Current_HVAC_Mode_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="state_variable">Current_Cool_Point_Setting_*</update_state_variable>
                <command_interface interface="ip">
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;t=</parameter>
                            <parameter state_variable="Current_Cool_Point_Setting_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                        </parameter_list>
                        <delay ms_delay="1000"></delay>
                    </command>
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;t=</parameter>
                            <parameter state_variable="Current_Cool_Point_Setting_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                        </parameter_list>
                        <delay ms_delay="1500"></delay>
                    </command>
                </command_interface>
            </action>
            <action name="SetHVACModeOff">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <update_state_variable name="Is_Current_HVAC_Mode_Heat_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">false</update_state_variable>
                <update_state_variable name="Is_Current_HVAC_Mode_Cool_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">false</update_state_variable>
                <update_state_variable name="Is_Current_HVAC_Mode_Off_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">true</update_state_variable>
                <update_state_variable name="Current_HVAC_Mode_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">0</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="constant">--</update_state_variable>
                <command_interface interface="ip">
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;t=20</parameter>
                        </parameter_list>
                        <delay ms_delay="1000"></delay>
                    </command>
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST">control?user=</command_string>
                        <parameter_list>
                            <parameter parameter_data_type="character"
                                state_variable="user_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pwd=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="password_gateway" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;cId=</parameter>
                            <parameter state_variable="controle_ar_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="6"
                                parameter_total_width="6">&amp;rcId=</parameter>
                            <parameter parameter_data_type="character"
                                state_variable="tipo_do_dispositivo" />
                            <parameter parameter_data_type="character" parameter_data_width="8"
                                parameter_total_width="8">&amp;state=2</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;tp=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="7"
                                parameter_total_width="7">&amp;type=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;p=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;m=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="3"
                                parameter_total_width="3">&amp;c=</parameter>
                            <parameter state_variable="canal_ir_*"
                                parameter_data_type="character"
                                wildcard_source_name="ThermostatAddress"
                                wildcard_source="action_argument" wildcard_format="%@" />
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;pw=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;md=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;v=1</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="4"
                                parameter_total_width="4">&amp;s=0</parameter>
                            <parameter parameter_data_type="character" parameter_data_width="5"
                                parameter_total_width="5">&amp;t=20</parameter>
                        </parameter_list>
                        <delay ms_delay="1500"></delay>
                    </command>
                </command_interface>
            </action>
            <action name="IncreaseCoolPointTemperature">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <action_argument name="CoolPointTemperature" note="" />
                <update_state_variable name="Current_Cool_Point_Setting_*" update_type="increment"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="state_variable">Current_Cool_Point_Setting_*</update_state_variable>

            </action>
            <action name="DecreaseCoolPointTemperature">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <action_argument name="CoolPointTemperature" note="" />
                <update_state_variable name="Current_Cool_Point_Setting_*" update_type="decrement"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="state_variable">Current_Cool_Point_Setting_*</update_state_variable>

            </action>
            <action name="IncreaseHeatPointTemperature">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <update_state_variable name="Current_Heat_Point_Setting_*" update_type="increment"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="state_variable">Current_Cool_Point_Setting_*</update_state_variable>

            </action>
            <action name="DecreaseHeatPointTemperature">
                <action_argument name="ThermostatAddress" note="Numero da zona (1-8)" />
                <update_state_variable name="Current_Heat_Point_Setting_*" update_type="decrement"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="HasReceivedCommand_*" update_type="set"
                    update_source="constant" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument" wildcard_format="%@">1</update_state_variable>
                <update_state_variable name="Thermostat_Current_Temperature_*" update_type="set"
                    wildcard_format="%d" wildcard_source_name="ThermostatAddress"
                    wildcard_source="action_argument"
                    update_source="state_variable">Current_Cool_Point_Setting_*</update_state_variable>

            </action>
            <entity name="Zone" address_components="1">
                <screen_representation>
                    <common_unique_identifier name="ThermostatAddress" address_component="1" />
                </screen_representation>
            </entity>
        </resource_component_actions>

        <custom_component_actions>
            <action name="KeepAlive">
                <command_interface interface="ip">
                    <command response_required="no">
                        <command_string type="character" http_request_type="POST"></command_string>
                        <delay ms_delay="500" />
                    </command>
                </command_interface>
                <execute_on_schedule period_ms="60000" />
            </action>
            <!--************************************************************************************************************************-->

        </custom_component_actions>
    </logical_component>
</component>